Systematic approach to diagnosing and fixing gas pool heater ignition and operation problems.
When your heater fails to start, follow this diagnostic sequence to identify the problem.
Verify breaker is on. Check for 120V or 240V at heater terminals depending on model.
Heater requires minimum flow to operate. Check pump is running and pressure is adequate.
Pressure switch must close to allow ignition. Bypass switch temporarily to test.
Confirm gas valve is open. Check for gas at burner by carefully opening manual valve.
Electronic ignitors should spark. Pilot igniters should produce flame. Replace if faulty.
High limit and rollout switches can prevent operation. Test continuity and reset if tripped.